    Examples programming SERS drives
   
    Syntax examples:
     
   
 
  ON will switch on the motor phase current
 
 
  OFF will switch off the motor phase current
 
 
  W=100
 
position command value is set to 100
(e.g. 100mm in case of linear scaling)
 
 
  V=1000
 
velocity is set to 1000
(e.g. 1000rpm in case of rotational scaling)
 
 
  A=2000
 
acceleration is set to 2000
(e.g. 2000rad/s2 in case of rotational scaling)
 
 
  E
execute – starts the positioning job
with the actual set position command value
 
 
  S Motor Stop
 
 
  RS right-slow – starts jog mode
 
 
  O3=1 output 3 will be set
 
     
    The syntax of all standard commands is defined as ASCII cleartext.
All other commands are specified as parameters.
     
    Parameter examples:
     
   
 
  P1010=4000 set motor phase current to 4000mA
 
 
  P1011=1
 
automatic current reduction at motor stand still
to 50% from adjusted phase current is activated
 
 
  P41=500
 
set homing velocity to 500
(e.g. 500rpm – depending on scaling)
 
 
  P1019=30
 
set jog slow velocity to 30
(e.g. 30rpm – depending on scaling)
 
     
    example standalone operational program:
     
   
 
  ON  
 
 
  L1  
 
 
  O1=1  
 
 
  W=350 E  
 
 
  O1=0  
 
 
  WAIT I1=1  
 
 
  W=-350 E  
 
 
  GOTO1  
 
     
    The programm first will switch on the phase current. Then the output O1 will be set,
the next position command value is defined and the positioning job is started.
After finishing the positioning job, the output O1 will be reset. Then the SERS waits
for the input I1 being set externally. Afterwards the distance "-350" will be executed
and finally there is a program jump back to Label L1.
       